Ground-Water Information Center Water Quality Report Site Name: LISTER, TRENTON AND ALLSA 
Report Date: 9/7/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 259012 / 126354 Sample Date: 6/10/2024 2:26:00 PM
Location (TRS): 01S 06E 07 CBDC Agency/Sampler: GLWQD / XIANG FAN
Latitude/Longitude: 45° 45' 42" N 111° 2' 17" W Field Number: GWMN-LIS2024
Datum: NAD83 Lab Date: 7/25/2024 10:34:40 AM
Altitude: 4843.58 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:1 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 120SDMS Total Depth (ft): 100
USGS 7.5' Quad: MISER CREEK SWL-MP (ft): 63.85
PWS Id: Depth Water Enters (ft): 55
Project: HAY_MSU, GWAAMON, GWCP08, 
NGWMN-MONTANA, BRIDGER, GWCP08MON, GALVAL
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 62.850 3.136 Bicarbonate (HCO3) 264.040 4.328
Magnesium (Mg) 16.810 1.383 Carbonate (CO3) 0.000 0.000
Sodium (Na) 3.450 0.150 Chloride (Cl) 7.920 0.223
Potassium (K) 2.080 0.053 Sulfate (SO4) 8.940 0.186
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 4.180 0.298
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.080 0.004
Silica (SiO2) 11.770 Orthophosphate (as P) 0.030 J 0.000
Total Cations 4.726 Total Anions 5.040
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.280 J Strontium (Sr): 100.250
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): <0.100 U Thallium (Tl): <0.100 U
Arsenic (As): <0.100 U Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 163.470 Copper (Cu): <0.500 U Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): 5.770 Palladium (Pd): <0.100 U Titanium (Ti): <0.100 U
Boron (B): 10.780 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 0.230 J Uranium (U): 1.350
Cadmium (Cd): <0.100 U Lithium (Li): 3.750 J Silver (Ag): <0.100 U Vanadium (V): <0.100 U
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 9.490
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 247.72 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 381.67 Hardness as CaCO3: 226.13 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 461.6 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 437.16 Alkalinity as CaCO3 (mg/L): 216.53 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.24 Ryznar Stability Index: 7.092 Field Nitrate (mg/L): NR
Lab pH: 7.64 Sodium Adsorption Ratio: 0.0868 Field Dissolved O2 (mg/L): 10.270
Water Temp (°C): 9.6 Langlier Saturation Index: 0.274 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 3.630 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 6.910 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.