Ground-Water Information Center Water Quality Report Site Name: GLWQD MONITORING WELL * YUKON 
Report Date: 4/19/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 253165 / 235475 Sample Date: 11/9/2021 10:21:00 AM
Location (TRS): 01S 04E 13 DBDA Agency/Sampler: MBMG / ENGLISH, ALAN
Latitude/Longitude: 45° 44' 54" N 111° 10' 11" W Field Number: 235475
Datum: NAD83 Lab Date: 12/13/2021 6:55:19 AM
Altitude: 4526.74 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:2 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 112SNGR Total Depth (ft): 73
USGS 7.5' Quad: BOZEMAN HOT SPRINGS SWL-MP (ft): 32.26
PWS Id: Depth Water Enters (ft): 58
Project: GALVAL, GWAAMON, GWCP08, 
GLWQDPHARM, NGWMN-MONTANA, BWIP4CSWL1, GWCP08MON, 
BWIP4C, BWIP4CCHEM
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 75.190 3.752 Bicarbonate (HCO3) 309.160 5.067
Magnesium (Mg) 16.760 1.379 Carbonate (CO3) 0.000 0.000
Sodium (Na) 8.750 0.381 Chloride (Cl) 4.980 0.140
Potassium (K) 3.380 0.086 Sulfate (SO4) 29.240 0.609
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 1.570 0.112
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.120 0.006
Silica (SiO2) 22.050 Orthophosphate (as P) 0.030 J 0.000
Total Cations 5.604 Total Anions 5.935
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.330 J Strontium (Sr): 202.300
Antimony (Sb): <0.100 U Chromium (Cr): 0.410 J Nickel (Ni): <0.100 U Thallium (Tl): <0.100 U
Arsenic (As): 0.440 Cobalt (Co): <0.100 U Niobium (Nb): 0.430 J Thorium (Th): <0.100 U
Barium (Ba): 181.920 Copper (Cu): 2.860 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): 8.170 Palladium (Pd): <0.100 U Titanium (Ti): 0.320 J
Boron (B): 11.660 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): 0.250 J
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.480 Uranium (U): 2.110
Cadmium (Cd): <0.100 U Lithium (Li): 2.390 J Silver (Ag): <0.100 U Vanadium (V): 1.710
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 9.770
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 314.18 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 470.96 Hardness as CaCO3: 256.73 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 514.9 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 478.72 Alkalinity as CaCO3 (mg/L): 253.43 Phosphorus, TD (mg/L): 0.040 J
Field pH: 7.39 Ryznar Stability Index: 7.010 Field Nitrate (mg/L): NR
Lab pH: 7.43 Sodium Adsorption Ratio: 0.2444 Field Dissolved O2 (mg/L): 7.370
Water Temp (°C): 10.9 Langlier Saturation Index: 0.210 Field Chloride (mg/L): NR
Air Temp (°C): 8 Nitrite (mg/L as N): <0.010 U Field Redox (mV): 139.2
Nitrate + Nitrite (mg/L as N) 1.460 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) NR Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition: CLEAR
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.