Ground-Water Information Center Water Quality Report Site Name: HOLT RANCH WORKSHOP WELL
Report Date: 4/24/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 223033 / 287546 Sample Date: 8/10/2017 11:30:00 AM
Location (TRS): 12N 20W 32 DAAC Agency/Sampler: MCWQD / ROSS, TRAVIS
Latitude/Longitude: 46° 45' 12" N 114° 7' 52" W Field Number: 287546
Datum: NAD83 Lab Date: 9/22/2017 8:06:38 AM
Altitude: 3275.693 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: MISSOULA / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:2 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 100UDFD Total Depth (ft): 80
USGS 7.5' Quad: BLUE MOUNTAIN SWL-MP (ft): NR
PWS Id: Depth Water Enters (ft): NR
Project: BWIPLO, BWIPLOMONGW, BWIPLOLITH1, 
BWIPLOLITHX, BWIPLO_CREEK
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 39.210 1.957 Bicarbonate (HCO3) 161.380 2.645
Magnesium (Mg) 9.360 0.770 Carbonate (CO3) 0.000 0.000
Sodium (Na) 5.040 0.219 Chloride (Cl) 8.040 0.227
Potassium (K) 1.940 0.050 Sulfate (SO4) 5.710 0.119
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 1.260 0.090
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.140 0.007
Silica (SiO2) 14.030 Orthophosphate (as P) 0.030 J 0.000
Total Cations 2.998 Total Anions 3.088
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.310 J Strontium (Sr): 59.880
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): <0.100 U Thallium (Tl): <0.100 U
Arsenic (As): <0.100 U Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 99.170 Copper (Cu): <0.500 U Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): 5.070 Palladium (Pd): <0.100 U Titanium (Ti): <0.100 U
Boron (B): 2.750 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 0.600 Uranium (U): 1.270
Cadmium (Cd): <0.100 U Lithium (Li): <2.000 U Silver (Ag): <0.100 U Vanadium (V): <0.100 U
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 6.870
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 163.89 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 245.58 Hardness as CaCO3: 136.43 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 225 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 269.25 Alkalinity as CaCO3 (mg/L): 132.05 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.58 Ryznar Stability Index: 7.582 Field Nitrate (mg/L): NR
Lab pH: 7.99 Sodium Adsorption Ratio: 0.1863 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 11.4 Langlier Saturation Index: 0.204 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 1.160 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) NR Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks: WATER CHEMISTRY MEASURED, WELL ON ALL DAY- PWL 28 FT
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.