Ground-Water Information Center Water Quality Report Site Name: NOTTINGHAM, MARIE/HOWARD, DAVE LC18
Report Date: 5/2/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 223024 / 290659 Sample Date: 8/9/2017 10:20:00 AM
Location (TRS): 12N 20W 35 DCC Agency/Sampler: MCWQD / ROSS, TRAVIS
Latitude/Longitude: 46° 44' 52" N 114° 4' 31" W Field Number: 290659
Datum: NAD83 Lab Date: 9/22/2017 8:06:38 AM
Altitude: 3170.355 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: MISSOULA / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:2 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 100UDFD Total Depth (ft): 23
USGS 7.5' Quad: FLORENCE SWL-MP (ft): 7.16
PWS Id: Depth Water Enters (ft): 18
Project: BWIPLOMONGW, BWIPLOLITH, BWIPLO, 
BWIPLOLITH1, BWIPLOLITHX, BWIPLOLITH2
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 10.750 0.536 Bicarbonate (HCO3) 60.990 1.000
Magnesium (Mg) 3.260 0.268 Carbonate (CO3) 0.000 0.000
Sodium (Na) 3.570 0.155 Chloride (Cl) 2.080 0.059
Potassium (K) 1.170 0.030 Sulfate (SO4) 3.330 0.069
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.090 0.006
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.270 0.014
Silica (SiO2) 13.800 Orthophosphate (as P) 0.090 J 0.000
Total Cations 0.991 Total Anions 1.148
Trace Element Results (µg/L)
Aluminum (Al): 4.080 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.290 J Strontium (Sr): 31.380
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): <0.100 U Thallium (Tl): <0.100 U
Arsenic (As): <0.100 U Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 31.690 Copper (Cu): 5.390 Neodymium (Nd): <0.100 U Tin (Sn): 0.500 J
Beryllium (Be): <0.100 U Gallium (Ga): 1.670 Palladium (Pd): <0.100 U Titanium (Ti): <0.100 U
Boron (B): 2.040 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.070 Uranium (U): <0.100 U
Cadmium (Cd): <0.100 U Lithium (Li): <2.000 U Silver (Ag): <0.100 U Vanadium (V): <0.100 U
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 0.570 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 68.06 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 99.02 Hardness as CaCO3: 40.26 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 76 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 92.29 Alkalinity as CaCO3 (mg/L): 50.03 Phosphorus, TD (mg/L): <0.030 U
Field pH: 5.85 Ryznar Stability Index: 10.519 Field Nitrate (mg/L): NR
Lab pH: 7.02 Sodium Adsorption Ratio: 0.2743 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 19 Langlier Saturation Index: -1.749 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) NR Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks: COLLECTED RADON TO U OF M
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.