Ground-Water Information Center Water Quality Report Site Name: MICECH JOE 
Report Date: 4/25/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 210658 / 244600 Sample Date: 3/25/2016 1:38:00 PM
Location (TRS): 01S 04E 03 BCCD Agency/Sampler: MBMG / BERZEL, MATT
Latitude/Longitude: 45° 46' 52" N 111° 13' 26" W Field Number: 244600
Datum: NAD83 Lab Date: 4/6/2016 2:05:41 PM
Altitude: 4428.36 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:1 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 111SNGR Total Depth (ft): 100
USGS 7.5' Quad: BELGRADE SWL-MP (ft): 53.32
PWS Id: Depth Water Enters (ft): 98.5
Project: RIVERROCK, GWCP08, GLWQDPHARM, 
BWIPMN
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 66.580 3.322 Bicarbonate (HCO3) 248.360 4.071
Magnesium (Mg) 20.110 1.655 Carbonate (CO3) 0.000 0.000
Sodium (Na) 30.610 1.332 Chloride (Cl) 46.210 1.304
Potassium (K) 3.170 0.081 Sulfate (SO4) 41.670 0.868
Iron (Fe) 0.039 J 0.000 Nitrate (as N) 5.220 0.373
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.200 0.011
Silica (SiO2) 22.120 Orthophosphate (as P) 0.030 J 0.000
Total Cations 6.407 Total Anions 6.625
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.680 Strontium (Sr): 375.030
Antimony (Sb): <0.100 U Chromium (Cr): 0.230 J Nickel (Ni): 3.430 Thallium (Tl): <0.100 U
Arsenic (As): 0.590 Cobalt (Co): 0.570 Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 128.790 Copper (Cu): 3.590 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): 4.960 Palladium (Pd): 0.200 J Titanium (Ti): 40.290
Boron (B): 94.150 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): 97.000 Lead (Pb): <0.060 U Rubidium (Rb): 1.910 Uranium (U): 2.020
Cadmium (Cd): <0.100 U Lithium (Li): 4.920 J Silver (Ag): <0.100 U Vanadium (V): 0.980
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 1.760 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 357.86 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 483.69 Hardness as CaCO3: 249.02 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 591 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 605.23 Alkalinity as CaCO3 (mg/L): 203.4 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.2 Ryznar Stability Index: 7.677 Field Nitrate (mg/L): NR
Lab pH: 6.96 Sodium Adsorption Ratio: 0.8548 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 12.2 Langlier Saturation Index: -0.358 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 4.380 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 5.000 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.