Ground-Water Information Center Water Quality Report Site Name: HOWARD MIKE 
Report Date: 4/26/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 210083 / 176459 Sample Date: 9/16/2015 1:42:00 PM
Location (TRS): 01S 04E 03 BC Agency/Sampler: MBMG / ENGLISH, ALAN
Latitude/Longitude: 45° 46' 55" N 111° 13' 26" W Field Number: 176459
Datum: NAD83 Lab Date: 10/13/2015 8:46:48 AM
Altitude: Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:2 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 110ALVM Total Depth (ft): 80
USGS 7.5' Quad: SWL-MP (ft): 46.52
PWS Id: Depth Water Enters (ft): 78.5
Project: RIVERROCK, BWIPMN, GALVAL_GW319
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 64.310 3.209 Bicarbonate (HCO3) 260.400 4.268
Magnesium (Mg) 18.300 1.506 Carbonate (CO3) 0.000 0.000
Sodium (Na) 11.400 0.496 Chloride (Cl) 18.440 0.520
Potassium (K) 2.480 0.063 Sulfate (SO4) 35.100 0.731
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 4.330 0.309
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.160 0.008
Silica (SiO2) 20.400 Orthophosphate (as P) 0.030 J 0.000
Total Cations 5.286 Total Anions 5.837
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.520 Strontium (Sr): 371.950
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 0.680 Thallium (Tl): <0.100 U
Arsenic (As): 0.590 Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 99.110 Copper (Cu): 0.570 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): 5.220 Palladium (Pd): 0.300 J Titanium (Ti): 42.700
Boron (B): 34.040 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.650 Uranium (U): 2.350
Cadmium (Cd): <0.100 U Lithium (Li): 5.250 J Silver (Ag): <0.100 U Vanadium (V): 1.060
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 14.300
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 300.7 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 432.62 Hardness as CaCO3: 235.9 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 588.5 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 497.82 Alkalinity as CaCO3 (mg/L): 213.24 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.35 Ryznar Stability Index: 7.366 Field Nitrate (mg/L): NR
Lab pH: 7.36 Sodium Adsorption Ratio: 0.3116 Field Dissolved O2 (mg/L): 6.490
Water Temp (°C): 10.3 Langlier Saturation Index: -0.003 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): 134.3
Nitrate + Nitrite (mg/L as N) 3.510 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 4.000 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition: CLEAR
Field Remarks: SAMPLE FROM FROST-FREE HYDRANT BY WELLHEAD
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.