Ground-Water Information Center Water Quality Report Site Name: PERRY GARY 
Report Date: 4/23/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 210078 / 176444 Sample Date: 9/10/2015 2:50:00 PM
Location (TRS): 01S 04E 02 CBD Agency/Sampler: / ENGLISH, ALAN
Latitude/Longitude: 45° 46' 38" N 111° 12' 5" W Field Number: 176444
Datum: NAD83 Lab Date: 10/13/2015 8:46:48 AM
Altitude: Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:2 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 110ALVM Total Depth (ft): 123
USGS 7.5' Quad: SWL-MP (ft): NR
PWS Id: Depth Water Enters (ft): 118.5
Project: RIVERROCK, BWIPMN
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 62.230 3.105 Bicarbonate (HCO3) 252.870 4.145
Magnesium (Mg) 16.630 1.368 Carbonate (CO3) 0.000 0.000
Sodium (Na) 7.000 0.305 Chloride (Cl) 4.410 0.124
Potassium (K) 3.180 0.081 Sulfate (SO4) 29.490 0.614
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 2.000 0.143
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.260 0.014
Silica (SiO2) 26.500 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.867 Total Anions 5.040
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.580 Strontium (Sr): 252.250
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): <0.100 U Thallium (Tl): <0.100 U
Arsenic (As): 1.040 Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 105.660 Copper (Cu): <0.500 U Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): 5.670 Palladium (Pd): 0.210 J Titanium (Ti): 46.440
Boron (B): 15.740 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): 0.300 Rubidium (Rb): 1.820 Uranium (U): 2.650
Cadmium (Cd): <0.100 U Lithium (Li): 3.760 J Silver (Ag): <0.100 U Vanadium (V): 1.680
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 5.420
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 275.5 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 403.87 Hardness as CaCO3: 223.84 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 503.5 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 424.17 Alkalinity as CaCO3 (mg/L): 207.5 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.73 Ryznar Stability Index: 7.128 Field Nitrate (mg/L): NR
Lab pH: 7.65 Sodium Adsorption Ratio: 0.2036 Field Dissolved O2 (mg/L): 7.250
Water Temp (°C): 11.3 Langlier Saturation Index: 0.261 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): 118
Nitrate + Nitrite (mg/L as N) 1.670 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 2.110 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition: CLEAR
Field Remarks: SAMPLE FROM FROST-FREE HYDRANT AT WELLHEAD
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.