Ground-Water Information Center Water Quality Report Site Name: WEST GALLATIN AT FRONTAGE RD WGFRRD
Report Date: 4/16/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 205296 / 257356 Sample Date: 10/9/2013 9:30:00 AM
Location (TRS): 01N 04E 19 AC Agency/Sampler: MBMG / SUTHERLAND, MARY
Latitude/Longitude: 45° 49' 29" N 111° 16' 16" W Field Number: 257356
Datum: NAD83 Lab Date: 1/22/2014 7:32:45 AM
Altitude: Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: MANHATTAN Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C, BWIP4CCHEM Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 39.380 1.965 Bicarbonate (HCO3) 146.200 2.396
Magnesium (Mg) 11.660 0.960 Carbonate (CO3) 0.000 0.000
Sodium (Na) 4.770 0.207 Chloride (Cl) 1.990 0.056
Potassium (K) 1.710 0.044 Sulfate (SO4) 39.740 0.828
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.070 0.005
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.230 0.012
Silica (SiO2) 11.570 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.181 Total Anions 3.297
Trace Element Results (µg/L)
Aluminum (Al): 2.040 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.850 Strontium (Sr): 210.430
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 1.100 Thallium (Tl): <0.100 U
Arsenic (As): 0.720 Cobalt (Co): 0.310 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 47.830 Copper (Cu): 0.410 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.440 J
Boron (B): 7.230 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 0.970 Uranium (U): 0.800
Cadmium (Cd): <0.100 U Lithium (Li): 2.050 J Silver (Ag): <0.100 U Vanadium (V): 0.690
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.270 J Zinc (Zn): <0.050 U
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 183.96 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 258.04 Hardness as CaCO3: 146.32 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 304 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 279.66 Alkalinity as CaCO3 (mg/L): 119.75 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.6 Ryznar Stability Index: 7.803 Field Nitrate (mg/L): NR
Lab pH: 7.85 Sodium Adsorption Ratio: 0.1799 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 6.8 Langlier Saturation Index: 0.024 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.