Ground-Water Information Center Water Quality Report Site Name: EAST GALLATIN AT PENWELL BRIDGE EGPWBR
Report Date: 4/26/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 205295 / 258311 Sample Date: 10/10/2013 10:40:00 AM
Location (TRS): 01N 05E 29 AC Agency/Sampler: / SUTHERLAND, MARY
Latitude/Longitude: 45° 48' 18" N 111° 7' 54" W Field Number: 258311
Datum: NAD83 Lab Date: 1/22/2014 7:32:45 AM
Altitude: Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 53.290 2.659 Bicarbonate (HCO3) 239.750 3.930
Magnesium (Mg) 16.090 1.324 Carbonate (CO3) 0.000 0.000
Sodium (Na) 13.940 0.606 Chloride (Cl) 14.280 0.403
Potassium (K) 3.700 0.095 Sulfate (SO4) 19.640 0.409
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.180 0.013
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.240 0.013
Silica (SiO2) 11.520 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.691 Total Anions 4.767
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.920 Strontium (Sr): 192.970
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 2.220 Thallium (Tl): <0.100 U
Arsenic (As): 0.810 Cobalt (Co): 0.300 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 58.300 Copper (Cu): 1.440 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.260 J
Boron (B): 23.770 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.960 Uranium (U): 1.820
Cadmium (Cd): <0.100 U Lithium (Li): <2.000 U Silver (Ag): <0.100 U Vanadium (V): 1.860
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.320 J Zinc (Zn): 3.860
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 251.61 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 373.38 Hardness as CaCO3: 199.29 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 434 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 420.7 Alkalinity as CaCO3 (mg/L): 196.84 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.78 Ryznar Stability Index: 6.928 Field Nitrate (mg/L): NR
Lab pH: 8.03 Sodium Adsorption Ratio: 0.4315 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 6.3 Langlier Saturation Index: 0.551 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 0.290 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.