Ground-Water Information Center Water Quality Report Site Name: GIBSON CREEK AT DRY CREEK SCHOOL ROAD GCDCSRD
Report Date: 4/25/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 205286 / 262881 Sample Date: 10/9/2013 12:40:00 PM
Location (TRS): 01N 04E 04 CB Agency/Sampler: MBMG / MICHALEK, TOM
Latitude/Longitude: 45° 52' 16" N 111° 13' 51" W Field Number: 262881
Datum: NAD83 Lab Date: 1/13/2014 2:53:50 PM
Altitude: Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 53.920 2.691 Bicarbonate (HCO3) 221.350 3.628
Magnesium (Mg) 16.000 1.317 Carbonate (CO3) 6.460 0.231
Sodium (Na) 8.100 0.352 Chloride (Cl) 4.320 0.122
Potassium (K) 2.860 0.073 Sulfate (SO4) 30.300 0.631
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.710 0.051
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.240 0.013
Silica (SiO2) 17.510 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.441 Total Anions 4.676
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.990 Strontium (Sr): 301.460
Antimony (Sb): <0.100 U Chromium (Cr): 0.380 J Nickel (Ni): 1.240 Thallium (Tl): <0.100 U
Arsenic (As): 0.740 Cobalt (Co): 0.270 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 87.320 Copper (Cu): <0.040 U Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.300 J
Boron (B): 13.150 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.550 Uranium (U): 1.810
Cadmium (Cd): <0.100 U Lithium (Li): <2.000 U Silver (Ag): <0.100 U Vanadium (V): 1.690
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): <0.050 U
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 248.79 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 360.92 Hardness as CaCO3: 200.49 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 483 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 393.87 Alkalinity as CaCO3 (mg/L): 191.27 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.72 Ryznar Stability Index: 6.683 Field Nitrate (mg/L): NR
Lab pH: 8.29 Sodium Adsorption Ratio: 0.2459 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 11.8 Langlier Saturation Index: 0.803 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 0.660 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.