Ground-Water Information Center Water Quality Report Site Name: USGS OBSERVATION WELL - PENWELL BRIDGE RD. 
Report Date: 4/25/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 205049 / 135735 Sample Date: 9/20/2013 12:35:00 PM
Location (TRS): 01N 04E 25 DCDD Agency/Sampler: MBMG / MICHALEK, TOM
Latitude/Longitude: 45° 48' 8" N 111° 9' 54" W Field Number: 135735
Datum: NAD83 Lab Date: 12/4/2013 7:35:58 AM
Altitude: 4389.444 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:1 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 110SNGR, 111SNGR Total Depth (ft): 101
USGS 7.5' Quad: BELGRADE SWL-MP (ft): 18.01
PWS Id: Depth Water Enters (ft): 10
Project: GWAAMON, GWCP08, NGWMN-MONTANA, 
BWIPMN, GALVAL
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 65.560 3.271 Bicarbonate (HCO3) 264.660 4.338
Magnesium (Mg) 17.390 1.431 Carbonate (CO3) 0.000 0.000
Sodium (Na) 13.240 0.576 Chloride (Cl) 18.300 0.516
Potassium (K) 3.780 0.097 Sulfate (SO4) 22.210 0.463
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 3.790 0.271
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.110 0.006
Silica (SiO2) 23.250 Orthophosphate (as P) 0.030 J 0.000
Total Cations 5.383 Total Anions 5.593
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.560 Strontium (Sr): 233.050
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 1.500 Thallium (Tl): <0.100 U
Arsenic (As): 1.010 Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 160.150 Copper (Cu): 1.980 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.210 J Titanium (Ti): 0.280 J
Boron (B): 29.550 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): 0.290 J Rubidium (Rb): 1.790 Uranium (U): 1.320
Cadmium (Cd): <0.100 U Lithium (Li): <2.000 U Silver (Ag): <0.100 U Vanadium (V): 1.880
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.360 J Zinc (Zn): 3.800
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 297.5 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 431.95 Hardness as CaCO3: 235.28 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 498 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 480.61 Alkalinity as CaCO3 (mg/L): 217.35 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.51 Ryznar Stability Index: 7.492 Field Nitrate (mg/L): NR
Lab pH: 7.2 Sodium Adsorption Ratio: 0.3688 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 12 Langlier Saturation Index: -0.146 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 3.470 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 3.520 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.