Ground-Water Information Center Water Quality Report Site Name: BURNT ROAD BRNRD2
Report Date: 4/26/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 204942 / 266834 Sample Date: 9/13/2013 10:07:00 AM
Location (TRS): 01N 04E 08 CC Agency/Sampler: MBMG / MICHALEK, TOM
Latitude/Longitude: 45° 50' 45" N 111° 15' 51" W Field Number: 266834
Datum: NAD83 Lab Date: 11/21/2013 7:09:29 AM
Altitude: 4274.974 Lab/Analyst: MBMG / TIMMER, JACKIE
County/State: GALLATIN / MT Sample Method/Handling: PUMPED / ru:1 ra:0 fu:1 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 111SNGR Total Depth (ft): 25
USGS 7.5' Quad: MANHATTAN SWL-MP (ft): 6.29
PWS Id: Depth Water Enters (ft): 15
Project: BWIPMN
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 49.250 2.458 Bicarbonate (HCO3) 200.440 3.285
Magnesium (Mg) 16.530 1.360 Carbonate (CO3) 0.000 0.000
Sodium (Na) 5.730 0.249 Chloride (Cl) 3.240 0.091
Potassium (K) 3.410 0.087 Sulfate (SO4) 40.040 0.834
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.490 0.035
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.260 0.014
Silica (SiO2) 21.320 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.162 Total Anions 4.259
Trace Element Results (µg/L)
Aluminum (Al): <2.000 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.800 Strontium (Sr): 302.020
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 1.030 Thallium (Tl): <0.100 U
Arsenic (As): 0.610 Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 63.240 Copper (Cu): 0.740 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.210 J Titanium (Ti): 0.410 J
Boron (B): 8.330 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.400 Uranium (U): 1.100
Cadmium (Cd): <0.100 U Lithium (Li): <1.500 U Silver (Ag): <0.100 U Vanadium (V): 1.250
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 1.220 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 237.3 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 338.78 Hardness as CaCO3: 191.01 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 380 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 356.15 Alkalinity as CaCO3 (mg/L): 164.03 Phosphorus, TD (mg/L): <0.030 U
Field pH: NR Ryznar Stability Index: 8.205 Field Nitrate (mg/L): NR
Lab pH: 6.88 Sodium Adsorption Ratio: 0.1889 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 12.9 Langlier Saturation Index: -0.663 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 0.550 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks: PH PROBE NOT WORKING
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.