Ground-Water Information Center Water Quality Report Site Name: REESE CREEK AT DRY CREEK ROAD RCDCRD
Report Date: 4/25/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 203564 / 264839 Sample Date: 4/4/2013 8:54:00 AM
Location (TRS): 01N 04E 12 DD Agency/Sampler: MBMG / MCGIVERN, AMBER
Latitude/Longitude: 45° 50' 58" N 111° 9' 34" W Field Number: 264839
Datum: NAD83 Lab Date: 5/13/2013 4:19:01 PM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 52.270 2.608 Bicarbonate (HCO3) 229.030 3.754
Magnesium (Mg) 14.090 1.159 Carbonate (CO3) 0.000 0.000
Sodium (Na) 6.560 0.285 Chloride (Cl) 4.460 0.126
Potassium (K) 1.720 0.044 Sulfate (SO4) 13.960 0.291
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 1.510 0.108
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.140 0.007
Silica (SiO2) 12.830 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.101 Total Anions 4.286
Trace Element Results (µg/L)
Aluminum (Al): 1.550 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.570 Strontium (Sr): 115.660
Antimony (Sb): <0.100 U Chromium (Cr): 1.310 Nickel (Ni): 1.040 Thallium (Tl): <0.100 U
Arsenic (As): 0.400 J Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 48.800 Copper (Cu): 4.310 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.280 J
Boron (B): 10.340 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 0.720 Uranium (U): 1.190
Cadmium (Cd): <0.100 U Lithium (Li): <1.500 U Silver (Ag): <0.100 U Vanadium (V): 1.290
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.410 J Zinc (Zn): 0.610 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 221.17 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 337.36 Hardness as CaCO3: 188.51 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 396 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 428 Alkalinity as CaCO3 (mg/L): 187.82 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.99 Ryznar Stability Index: 7.266 Field Nitrate (mg/L): NR
Lab pH: 7.75 Sodium Adsorption Ratio: 0.2219 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 6.6 Langlier Saturation Index: 0.242 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 1.380 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 2.500 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.