Ground-Water Information Center Water Quality Report Site Name: DRY CREEK AT FRONTAGE RD. DCFRRD
Report Date: 3/29/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 203562 / 265153 Sample Date: 4/4/2013 11:49:00 AM
Location (TRS): 01S 05E 17 BB Agency/Sampler: MBMG / MCGIVERN, AMBER
Latitude/Longitude: 45° 45' 28" N 111° 8' 30" W Field Number: 265153
Datum: NAD83 Lab Date: 5/13/2013 4:19:01 PM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 55.080 2.748 Bicarbonate (HCO3) 242.470 3.974
Magnesium (Mg) 15.540 1.279 Carbonate (CO3) 8.570 0.307
Sodium (Na) 10.690 0.465 Chloride (Cl) 4.580 0.129
Potassium (K) 3.130 0.080 Sulfate (SO4) 15.520 0.323
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 1.180 0.084
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.190 0.010
Silica (SiO2) 17.960 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.578 Total Anions 4.828
Trace Element Results (µg/L)
Aluminum (Al): 2.680 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.700 Strontium (Sr): 156.140
Antimony (Sb): <0.100 U Chromium (Cr): 0.260 J Nickel (Ni): 1.440 Thallium (Tl): <0.100 U
Arsenic (As): 1.110 Cobalt (Co): 0.210 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 78.960 Copper (Cu): 1.130 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.400 J
Boron (B): 14.030 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.580 Uranium (U): 2.910
Cadmium (Cd): <0.100 U Lithium (Li): <1.500 U Silver (Ag): <0.100 U Vanadium (V): 3.690
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.340 J Zinc (Zn): <0.050 U
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 252.83 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 375.62 Hardness as CaCO3: 201.5 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 425 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 458 Alkalinity as CaCO3 (mg/L): 213.49 Phosphorus, TD (mg/L): <0.030 U
Field pH: 9.01 Ryznar Stability Index: 6.529 Field Nitrate (mg/L): NR
Lab pH: 8.33 Sodium Adsorption Ratio: 0.3372 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 9.9 Langlier Saturation Index: 0.900 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): 0.060 Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 1.120 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 1.120 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.