Ground-Water Information Center Water Quality Report Site Name: CASEY, JIM & ILENE 
Report Date: 4/25/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 203510 / 9518 Sample Date: 3/19/2013 2:42:00 PM
Location (TRS): 01N 04E 06 BAA Agency/Sampler: MBMG / SCOTT/MCGIVERN
Latitude/Longitude: 45° 52' 28" N 111° 16' 10" W Field Number: 9518
Datum: NAD83 Lab Date: 4/24/2013 10:09:44 PM
Altitude: 4245 Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 111ALVM Total Depth (ft): 62.5
USGS 7.5' Quad: MANHATTAN SWL-MP (ft): NR
PWS Id: Depth Water Enters (ft): 62.5
Project: BWIPMN
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 100.700 5.025 Bicarbonate (HCO3) 381.790 6.258
Magnesium (Mg) 28.540 2.349 Carbonate (CO3) 0.000 0.000
Sodium (Na) 22.910 0.997 Chloride (Cl) 9.500 0.268
Potassium (K) 3.590 0.092 Sulfate (SO4) 127.600 2.658
Iron (Fe) 0.629 0.023 Nitrate (as N) <0.010 U 0.000
Manganese (Mn) 2.025 0.074 Fluoride (F) 0.320 0.017
Silica (SiO2) 27.870 Orthophosphate (as P) <0.020 U 0.000
Total Cations 8.570 Total Anions 9.200
Trace Element Results (µg/L)
Aluminum (Al): <0.400 U Cesium (Cs): <0.100 U Molybdenum (Mo): 1.870 Strontium (Sr): 458.750
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 2.690 Thallium (Tl): <0.100 U
Arsenic (As): 4.290 Cobalt (Co): 0.760 Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 258.270 Copper (Cu): <0.040 U Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.220 J Titanium (Ti): 1.340
Boron (B): 12.230 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): 1.590
Bromide (Br): <10.000 U Lead (Pb): <0.060 U Rubidium (Rb): 1.880 Uranium (U): 1.430
Cadmium (Cd): <0.100 U Lithium (Li): <1.500 U Silver (Ag): <0.100 U Vanadium (V): 0.360 J
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.230 J Zinc (Zn): 5.210
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 513.42 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 707.25 Hardness as CaCO3: 368.92 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 777 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 786.5 Alkalinity as CaCO3 (mg/L): 313.31 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.33 Ryznar Stability Index: 6.762 Field Nitrate (mg/L): NR
Lab pH: 7.24 Sodium Adsorption Ratio: 0.5211 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 9.4 Langlier Saturation Index: 0.239 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks: REANALYZED AND RESULTS CONFIRMED
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.