Ground-Water Information Center Water Quality Report Site Name: EAST GALLATIN AT GALLATIN RIVER RANCH EGGRR
Report Date: 4/28/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202787 / 257433 Sample Date: 9/21/2012 9:35:00 AM
Location (TRS): 02N 03E 27 DC Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 53' 31" N 111° 19' 55" W Field Number: 257433
Datum: NAD83 Lab Date: 1/23/2013 1:02:53 PM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: NIXON GULCH Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 52.430 2.616 Bicarbonate (HCO3) 221.420 3.629
Magnesium (Mg) 15.830 1.303 Carbonate (CO3) 0.000 0.000
Sodium (Na) 8.180 0.356 Chloride (Cl) 6.720 0.190
Potassium (K) 2.820 0.072 Sulfate (SO4) 20.660 0.430
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.620 0.044
Manganese (Mn) 0.005 J 0.000 Fluoride (F) 0.150 0.008
Silica (SiO2) 15.830 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.353 Total Anions 4.301
Trace Element Results (µg/L)
Aluminum (Al): 1.460 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.620 Strontium (Sr): 192.220
Antimony (Sb): <0.100 U Chromium (Cr): 0.340 J Nickel (Ni): 1.110 Thallium (Tl): <0.100 U
Arsenic (As): 0.880 Cobalt (Co): 0.290 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 72.020 Copper (Cu): 0.240 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.100 J Titanium (Ti): 0.300 J
Boron (B): 15.450 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.230 Uranium (U): 0.890
Cadmium (Cd): <0.100 U Lithium (Li): 4.630 Silver (Ag): <0.100 U Vanadium (V): 1.990
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.260 J Zinc (Zn): <0.200 U
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 233.13 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 345.26 Hardness as CaCO3: 196.07 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 406 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 419.8 Alkalinity as CaCO3 (mg/L): 181.26 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.21 Ryznar Stability Index: 6.854 Field Nitrate (mg/L): NR
Lab pH: 8.19 Sodium Adsorption Ratio: 0.2486 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 12.1 Langlier Saturation Index: 0.668 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 0.840 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 1.140 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.