Ground-Water Information Center Water Quality Report Site Name: WEST GALLATIN AT AMSTERDAM RD WGAMRD
Report Date: 4/19/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202784 / 257355 Sample Date: 9/21/2012 3:45:00 PM
Location (TRS): 01S 04E 04 CD Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 46' 21" N 111° 14' 20" W Field Number: 257355
Datum: NAD83 Lab Date: 1/23/2013 1:02:53 PM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C, BWIP4CCHEM Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 41.040 2.048 Bicarbonate (HCO3) 133.850 2.194
Magnesium (Mg) 11.710 0.964 Carbonate (CO3) 0.000 0.000
Sodium (Na) 4.380 0.191 Chloride (Cl) 1.830 0.052
Potassium (K) 1.880 0.048 Sulfate (SO4) 42.700 0.889
Iron (Fe) <0.015 U 0.000 Nitrate (as N) <0.010 U 0.000
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.200 0.011
Silica (SiO2) 10.930 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.256 Total Anions 3.145
Trace Element Results (µg/L)
Aluminum (Al): 0.670 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.960 Strontium (Sr): 214.570
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 1.320 Thallium (Tl): <0.100 U
Arsenic (As): 1.760 Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 50.100 Copper (Cu): <0.100 U Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.530
Boron (B): 6.850 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.280 Uranium (U): 0.870
Cadmium (Cd): <0.100 U Lithium (Li): 1.790 J Silver (Ag): <0.100 U Vanadium (V): 0.450 J
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 0.320 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 180.76 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 248.75 Hardness as CaCO3: 150.68 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): NR Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 312.2 Alkalinity as CaCO3 (mg/L): 109.9 Phosphorus, TD (mg/L): <0.030 U
Field pH: NR Ryznar Stability Index: 7.442 Field Nitrate (mg/L): NR
Lab pH: 8.25 Sodium Adsorption Ratio: 0.1418 Field Dissolved O2 (mg/L): NR
Water Temp (°C): NR Langlier Saturation Index: 0.404 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.