Ground-Water Information Center Water Quality Report Site Name: BULL RUN CREEK AT SALES ROAD BRCSRD
Report Date: 4/23/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202719 / 262933 Sample Date: 9/6/2012 3:20:00 PM
Location (TRS): 01N 04E 06 BAA Agency/Sampler: BWTF / SCOTT, JEFF
Latitude/Longitude: 45° 52' 29" N 111° 16' 8" W Field Number: 262933
Datum: NAD83 Lab Date: 12/18/2012 7:39:08 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: MANHATTAN Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 46.890 2.340 Bicarbonate (HCO3) 164.470 2.696
Magnesium (Mg) 17.110 1.408 Carbonate (CO3) 10.470 0.375
Sodium (Na) 6.690 0.291 Chloride (Cl) 4.790 0.135
Potassium (K) 3.100 0.079 Sulfate (SO4) 34.360 0.716
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.190 0.014
Manganese (Mn) <0.002 U 0.000 Fluoride (F) 0.160 0.008
Silica (SiO2) 12.070 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.126 Total Anions 3.943
Trace Element Results (µg/L)
Aluminum (Al): 2.150 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.790 Strontium (Sr): 286.120
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 1.870 Thallium (Tl): <0.100 U
Arsenic (As): 0.630 Cobalt (Co): 0.190 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 69.960 Copper (Cu): 0.200 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.160 J Titanium (Ti): 0.530
Boron (B): 9.190 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.660 Uranium (U): 1.640
Cadmium (Cd): <0.100 U Lithium (Li): 4.530 Silver (Ag): <0.100 U Vanadium (V): 1.890
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.190 J Zinc (Zn): 0.340 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 215.79 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 299 Hardness as CaCO3: 187.51 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 365 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 343.1 Alkalinity as CaCO3 (mg/L): 151.19 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.76 Ryznar Stability Index: 6.629 Field Nitrate (mg/L): NR
Lab pH: 8.67 Sodium Adsorption Ratio: 0.2224 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 18.6 Langlier Saturation Index: 1.021 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 4.510 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 4.870 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.