Ground-Water Information Center Water Quality Report Site Name: REESE CREEK AT DRY CREEK ROAD RCDCRD
Report Date: 4/24/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202718 / 264839 Sample Date: 9/7/2012 2:10:00 PM
Location (TRS): 01N 04E 12 DD Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 50' 58" N 111° 9' 34" W Field Number: 264839
Datum: NAD83 Lab Date: 12/18/2012 7:39:08 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 51.850 2.587 Bicarbonate (HCO3) 217.180 3.560
Magnesium (Mg) 15.550 1.280 Carbonate (CO3) 0.000 0.000
Sodium (Na) 7.250 0.315 Chloride (Cl) 4.750 0.134
Potassium (K) 2.230 0.057 Sulfate (SO4) 13.160 0.274
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 1.030 0.074
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.130 0.007
Silica (SiO2) 13.530 Orthophosphate (as P) <0.020 U 0.000
Total Cations 4.243 Total Anions 4.048
Trace Element Results (µg/L)
Aluminum (Al): 1.500 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.590 Strontium (Sr): 125.770
Antimony (Sb): <0.100 U Chromium (Cr): 0.930 Nickel (Ni): 1.160 Thallium (Tl): <0.100 U
Arsenic (As): 0.510 Cobalt (Co): 0.100 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 49.170 Copper (Cu): 0.400 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): <0.100 U
Boron (B): 11.690 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 0.970 Uranium (U): 1.140
Cadmium (Cd): <0.100 U Lithium (Li): <0.400 U Silver (Ag): <0.100 U Vanadium (V): 1.810
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.370 J Zinc (Zn): 0.520 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 216.3 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 326.4 Hardness as CaCO3: 193.47 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 380 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 358.1 Alkalinity as CaCO3 (mg/L): 177.98 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.33 Ryznar Stability Index: 6.820 Field Nitrate (mg/L): NR
Lab pH: 8.25 Sodium Adsorption Ratio: 0.219 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 14.8 Langlier Saturation Index: 0.715 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 1.070 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 1.760 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.