Ground-Water Information Center Water Quality Report Site Name: WEST GALLATIN AT AMSTERDAM RD WGAMRD
Report Date: 5/10/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202232 / 257355 Sample Date: 7/26/2012 8:30:00 AM
Location (TRS): 01S 04E 04 CD Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 46' 21" N 111° 14' 20" W Field Number: 257355
Datum: NAD83 Lab Date: 10/9/2012 7:18:15 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C, BWIP4CCHEM Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 33.100 1.652 Bicarbonate (HCO3) 120.270 1.971
Magnesium (Mg) 9.600 0.790 Carbonate (CO3) 0.000 0.000
Sodium (Na) 4.210 0.183 Chloride (Cl) 1.460 0.041
Potassium (K) 1.640 0.042 Sulfate (SO4) 29.740 0.619
Iron (Fe) <0.015 U 0.000 Nitrate (as N) <0.010 U 0.000
Manganese (Mn) 0.002 J 0.000 Fluoride (F) 0.170 0.009
Silica (SiO2) 11.240 Orthophosphate (as P) <0.020 U 0.000
Total Cations 2.672 Total Anions 2.641
Trace Element Results (µg/L)
Aluminum (Al): <0.400 U Cesium (Cs): <0.100 U Molybdenum (Mo): 0.770 Strontium (Sr): 180.610
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 0.710 Thallium (Tl): <0.100 U
Arsenic (As): 0.750 Cobalt (Co): 0.200 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 64.630 Copper (Cu): 0.130 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.380 J
Boron (B): 8.190 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.150 Uranium (U): 0.560
Cadmium (Cd): <0.100 U Lithium (Li): 2.810 Silver (Ag): <0.100 U Vanadium (V): 0.790
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.100 J Zinc (Zn): <0.200 U
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 149.81 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 210.7 Hardness as CaCO3: 122.16 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 264 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 253.8 Alkalinity as CaCO3 (mg/L): 98.42 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.32 Ryznar Stability Index: 8.004 Field Nitrate (mg/L): NR
Lab pH: 7.97 Sodium Adsorption Ratio: 0.1575 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 16.4 Langlier Saturation Index: -0.017 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.