Ground-Water Information Center Water Quality Report Site Name: GALLATIN RIVER AT NIXON GULCH RD GRNGRD
Report Date: 4/28/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202221 / 257431 Sample Date: 7/24/2012 11:59:00 AM
Location (TRS): 02N 03E 27 CC Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 53' 29" N 111° 20' 13" W Field Number: 257431
Datum: NAD83 Lab Date: 10/9/2012 7:18:15 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: NIXON GULCH Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 41.390 2.065 Bicarbonate (HCO3) 171.650 2.813
Magnesium (Mg) 12.930 1.064 Carbonate (CO3) 0.000 0.000
Sodium (Na) 6.370 0.277 Chloride (Cl) 3.610 0.102
Potassium (K) 2.480 0.063 Sulfate (SO4) 25.730 0.536
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.170 0.012
Manganese (Mn) 0.005 J 0.000 Fluoride (F) 0.160 0.008
Silica (SiO2) 13.740 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.477 Total Anions 3.472
Trace Element Results (µg/L)
Aluminum (Al): 17.570 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.760 Strontium (Sr): 193.840
Antimony (Sb): <0.100 U Chromium (Cr): 0.170 J Nickel (Ni): 1.460 Thallium (Tl): <0.100 U
Arsenic (As): 0.930 Cobalt (Co): 0.200 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 79.700 Copper (Cu): 0.450 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.120 J Titanium (Ti): 0.390 J
Boron (B): 13.140 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.260 Uranium (U): 0.940
Cadmium (Cd): <0.100 U Lithium (Li): 2.090 Silver (Ag): <0.100 U Vanadium (V): 1.410
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.340 J Zinc (Zn): 0.470 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 191.07 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 278.34 Hardness as CaCO3: 156.57 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 319 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 319.5 Alkalinity as CaCO3 (mg/L): 141.07 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.6 Ryznar Stability Index: 7.297 Field Nitrate (mg/L): NR
Lab pH: 8.17 Sodium Adsorption Ratio: 0.2087 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 19.3 Langlier Saturation Index: 0.436 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.