Ground-Water Information Center Water Quality Report Site Name: HYALITE CREEK AT VALLEY CTR RD HYVCRD
Report Date: 4/26/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 202215 / 257394 Sample Date: 7/17/2012 2:50:00 PM
Location (TRS): 01S 05E 19 CD Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 43' 45" N 111° 9' 17" W Field Number: 257394
Datum: NAD83 Lab Date: 10/9/2012 7:18:15 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BOZEMAN HOT SPRINGS Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C, BWIP4CCHEM Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 32.870 1.640 Bicarbonate (HCO3) 134.860 2.210
Magnesium (Mg) 9.710 0.799 Carbonate (CO3) 0.000 0.000
Sodium (Na) 4.820 0.210 Chloride (Cl) 1.510 0.043
Potassium (K) 2.000 0.051 Sulfate (SO4) 21.360 0.445
Iron (Fe) <0.015 U 0.000 Nitrate (as N) 0.070 0.005
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.140 0.007
Silica (SiO2) 11.870 Orthophosphate (as P) <0.020 U 0.000
Total Cations 2.704 Total Anions 2.710
Trace Element Results (µg/L)
Aluminum (Al): 2.020 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.680 Strontium (Sr): 150.720
Antimony (Sb): <0.100 U Chromium (Cr): 0.130 J Nickel (Ni): 0.960 Thallium (Tl): <0.100 U
Arsenic (As): 0.710 Cobalt (Co): 0.150 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 61.800 Copper (Cu): 0.380 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.350 J
Boron (B): 7.660 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.480 Uranium (U): 0.720
Cadmium (Cd): <0.100 U Lithium (Li): <0.400 U Silver (Ag): <0.100 U Vanadium (V): 1.320
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.190 J Zinc (Zn): <0.200 U
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 151.08 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 219.58 Hardness as CaCO3: 122.04 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 249 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 244.8 Alkalinity as CaCO3 (mg/L): 110.72 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.72 Ryznar Stability Index: 7.608 Field Nitrate (mg/L): NR
Lab pH: 8.27 Sodium Adsorption Ratio: 0.1969 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 21.3 Langlier Saturation Index: 0.331 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.