Ground-Water Information Center Water Quality Report Site Name: EAST GALLATIN AT PENWELL BRIDGE EGPWBR
Report Date: 4/19/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 201743 / 258311 Sample Date: 5/18/2012 9:35:00 AM
Location (TRS): 01N 05E 29 AC Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 48' 18" N 111° 7' 54" W Field Number: 258311
Datum: NAD83 Lab Date: 8/9/2012 7:08:28 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 40.370 2.014 Bicarbonate (HCO3) 174.040 2.853
Magnesium (Mg) 10.530 0.867 Carbonate (CO3) 0.000 0.000
Sodium (Na) 7.910 0.344 Chloride (Cl) 5.280 0.149
Potassium (K) 1.660 0.042 Sulfate (SO4) 10.260 0.214
Iron (Fe) 0.015 J 0.000 Nitrate (as N) 0.140 0.010
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.130 0.007
Silica (SiO2) 11.240 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.273 Total Anions 3.232
Trace Element Results (µg/L)
Aluminum (Al): 11.030 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.440 J Strontium (Sr): 133.790
Antimony (Sb): <0.100 U Chromium (Cr): 0.200 J Nickel (Ni): 1.200 Thallium (Tl): <0.100 U
Arsenic (As): 0.740 Cobalt (Co): 0.580 Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 47.220 Copper (Cu): 0.700 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.330 J
Boron (B): 13.670 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 0.780 Uranium (U): 0.660
Cadmium (Cd): <0.100 U Lithium (Li): 4.960 Silver (Ag): <0.100 U Vanadium (V): 1.110
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.220 J Zinc (Zn): 1.430
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 172.63 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 260.91 Hardness as CaCO3: 144.15 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 297 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 356.6 Alkalinity as CaCO3 (mg/L): 142.71 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.46 Ryznar Stability Index: 7.469 Field Nitrate (mg/L): NR
Lab pH: 8.01 Sodium Adsorption Ratio: 0.29 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 10.3 Langlier Saturation Index: 0.271 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.