Ground-Water Information Center Water Quality Report Site Name: EAST GALLATIN AT GALLATIN RIVER RANCH EGGRR
Report Date: 4/28/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 201741 / 257433 Sample Date: 5/17/2012 1:25:00 PM
Location (TRS): 02N 03E 27 DC Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 53' 31" N 111° 19' 55" W Field Number: 257433
Datum: NAD83 Lab Date: 8/9/2012 7:08:28 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: NIXON GULCH Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 46.930 2.342 Bicarbonate (HCO3) 201.470 3.302
Magnesium (Mg) 12.820 1.055 Carbonate (CO3) 0.000 0.000
Sodium (Na) 7.580 0.330 Chloride (Cl) 5.370 0.151
Potassium (K) 2.100 0.054 Sulfate (SO4) 14.090 0.293
Iron (Fe) 0.011 J 0.000 Nitrate (as N) 0.360 0.026
Manganese (Mn) 0.006 J 0.000 Fluoride (F) 0.130 0.007
Silica (SiO2) 13.080 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.786 Total Anions 3.780
Trace Element Results (µg/L)
Aluminum (Al): 7.780 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.510 Strontium (Sr): 155.300
Antimony (Sb): <0.100 U Chromium (Cr): 0.370 J Nickel (Ni): 1.840 Thallium (Tl): <0.100 U
Arsenic (As): 0.910 Cobalt (Co): 0.330 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 56.740 Copper (Cu): 0.620 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.550
Boron (B): 16.170 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 0.860 Uranium (U): 0.920
Cadmium (Cd): <0.100 U Lithium (Li): 4.440 Silver (Ag): <0.100 U Vanadium (V): 1.580
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.290 J Zinc (Zn): 0.350 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 200.77 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 302.76 Hardness as CaCO3: 169.95 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 342 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 413.5 Alkalinity as CaCO3 (mg/L): 164.85 Phosphorus, TD (mg/L): <0.030 U
Field pH: 4.04 Ryznar Stability Index: 7.023 Field Nitrate (mg/L): NR
Lab pH: 8.2 Sodium Adsorption Ratio: 0.267 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 17.2 Langlier Saturation Index: 0.589 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 0.350 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.