Ground-Water Information Center Water Quality Report Site Name: EAST GALLATIN AT DRY CREEK SCHOOL ROAD EGDCSRD
Report Date: 4/25/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 201739 / 262900 Sample Date: 5/17/2012 10:35:00 AM
Location (TRS): 01N 04E 04 DA Agency/Sampler: BLM / SCOTT, JEFF
Latitude/Longitude: 45° 52' 14" N 111° 13' 22" W Field Number: 262900
Datum: NAD83 Lab Date: 8/9/2012 7:08:28 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 46.830 2.337 Bicarbonate (HCO3) 199.250 3.266
Magnesium (Mg) 12.500 1.029 Carbonate (CO3) 0.000 0.000
Sodium (Na) 7.300 0.318 Chloride (Cl) 5.460 0.154
Potassium (K) 2.120 0.054 Sulfate (SO4) 12.660 0.264
Iron (Fe) 0.012 J 0.000 Nitrate (as N) 0.420 0.030
Manganese (Mn) 0.004 J 0.000 Fluoride (F) 0.130 0.007
Silica (SiO2) 12.940 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.743 Total Anions 3.720
Trace Element Results (µg/L)
Aluminum (Al): 9.440 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.240 J Strontium (Sr): 147.940
Antimony (Sb): <0.100 U Chromium (Cr): 0.300 J Nickel (Ni): 1.260 Thallium (Tl): <0.100 U
Arsenic (As): 0.780 Cobalt (Co): 0.540 Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 55.670 Copper (Cu): 0.560 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.680
Boron (B): 12.510 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 0.810 Uranium (U): 0.900
Cadmium (Cd): <0.100 U Lithium (Li): 4.060 Silver (Ag): <0.100 U Vanadium (V): 1.420
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.270 J Zinc (Zn): 0.780 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 197.37 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 298.34 Hardness as CaCO3: 168.38 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 340 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 402.8 Alkalinity as CaCO3 (mg/L): 163.21 Phosphorus, TD (mg/L): <0.030 U
Field pH: 7.34 Ryznar Stability Index: 7.153 Field Nitrate (mg/L): NR
Lab pH: 8.08 Sodium Adsorption Ratio: 0.2347 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 13.1 Langlier Saturation Index: 0.463 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 0.400 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.