Ground-Water Information Center Water Quality Report Site Name: HYALITE CREEK AT VALLEY CTR RD HYVCRD
Report Date: 4/22/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 201651 / 257394 Sample Date: 5/2/2012 2:20:00 PM
Location (TRS): 01S 05E 19 CD Agency/Sampler: MBMG / SCOTT, JEFF
Latitude/Longitude: 45° 43' 45" N 111° 9' 17" W Field Number: 257394
Datum: NAD83 Lab Date: 7/3/2012 3:04:49 PM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BOZEMAN HOT SPRINGS Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C, BWIP4CCHEM Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 16.670 0.832 Bicarbonate (HCO3) 76.150 1.248
Magnesium (Mg) 4.180 0.344 Carbonate (CO3) 0.000 0.000
Sodium (Na) 2.220 0.097 Chloride (Cl) 0.930 0.026
Potassium (K) 1.440 0.037 Sulfate (SO4) 3.690 0.077
Iron (Fe) 0.042 0.002 Nitrate (as N) <0.010 U 0.000
Manganese (Mn) 0.002 J 0.000 Fluoride (F) 0.080 0.004
Silica (SiO2) 15.680 Orthophosphate (as P) <0.020 U 0.000
Total Cations 1.317 Total Anions 1.355
Trace Element Results (µg/L)
Aluminum (Al): 42.790 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.210 J Strontium (Sr): 52.330
Antimony (Sb): <0.100 U Chromium (Cr): <0.100 U Nickel (Ni): 0.600 Thallium (Tl): <0.100 U
Arsenic (As): 0.640 Cobalt (Co): <0.100 U Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 25.910 Copper (Cu): 3.720 Neodymium (Nd): 0.100 J Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 1.400
Boron (B): 3.920 Lanthanum (La): 0.100 J Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.580 Uranium (U): 0.370 J
Cadmium (Cd): <0.100 U Lithium (Li): 0.940 J Silver (Ag): <0.100 U Vanadium (V): 0.970
Cerium (Ce): 0.210 J Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 0.750 J
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 82.34 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 120.9 Hardness as CaCO3: 58.83 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 137 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 159.7 Alkalinity as CaCO3 (mg/L): 62.33 Phosphorus, TD (mg/L): <0.030 U
Field pH: 8.17 Ryznar Stability Index: 9.217 Field Nitrate (mg/L): NR
Lab pH: 7.75 Sodium Adsorption Ratio: 0.1135 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 9 Langlier Saturation Index: -0.733 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.