Ground-Water Information Center Water Quality Report Site Name: HYALITE CREEK AT FRONTAGE RD. HYFRRD
Report Date: 4/23/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 2011Q0376 / 257396 Sample Date: 8/27/2010 10:00:00 AM
Location (TRS): 01S 05E 17 AC Agency/Sampler: MBMG / SCHAEFFER, MARK
Latitude/Longitude: 45° 45' 7" N 111° 7' 57" W Field Number: HYFRRD
Datum: NAD83 Lab Date: 12/9/2010
Altitude: Lab/Analyst: MBMG / SM
County/State: GALLATIN / MT Sample Method/Handling: GRAB / 4000
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: BELGRADE Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN, BWIP4C, BWIP4CCHEM Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 39.300 1.961 Bicarbonate (HCO3) 149.100 2.444
Magnesium (Mg) 11.300 0.930 Carbonate (CO3) 0.000 0.000
Sodium (Na) 6.000 0.261 Chloride (Cl) 1.890 0.053
Potassium (K) 2.130 0.054 Sulfate (SO4) 29.600 0.617
Iron (Fe) <0.002 0.000 Nitrate (as N) 0.111 0.008
Manganese (Mn) 0.003 0.000 Fluoride (F) 0.179 0.009
Silica (SiO2) 13.100 Orthophosphate (as P) <0.1 0.000
Total Cations 3.212 Total Anions 3.131
Trace Element Results (µg/L)
Aluminum (Al): 2.340 Cesium (Cs): <0.5 Molybdenum (Mo): 0.831 Strontium (Sr): 182.000
Antimony (Sb): <0.2 Chromium (Cr): <0.2 Nickel (Ni): 0.232 Thallium (Tl): <0.2
Arsenic (As): 0.808 Cobalt (Co): 1.100 Niobium (Nb): <0.2 Thorium (Th): <0.2
Barium (Ba): 52.600 Copper (Cu): <0.5 Neodymium (Nd): <0.2 Tin (Sn): <0.2
Beryllium (Be): <0.2 Gallium (Ga): <0.2 Palladium (Pd): <0.5 Titanium (Ti): 0.468
Boron (B): 9.260 Lanthanum (La): <0.2 Praseodymium (Pr): <0.2 Tungsten (W): <0.2
Bromide (Br): <50 Lead (Pb): <0.2 Rubidium (Rb): 1.630 Uranium (U): 0.960
Cadmium (Cd): <0.2 Lithium (Li): 2.060 Silver (Ag): <0.2 Vanadium (V): 1.490
Cerium (Ce): <0.2 Mercury (Hg): NR Selenium (Se): 0.197 Zinc (Zn): <1.0
Zirconium (Zr): <0.2
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 177 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 252.6 Hardness as CaCO3: 144.64 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): NR Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 291 Alkalinity as CaCO3 (mg/L): 122.21 Phosphorus, TD (mg/L): <0.070
Field pH: NR Ryznar Stability Index: 7.367 Field Nitrate (mg/L): NR
Lab pH: 8.27 Sodium Adsorption Ratio: 0.2171 Field Dissolved O2 (mg/L): NR
Water Temp (°C): NR Langlier Saturation Index: 0.451 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.05 Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.2 Hydroxide (mg/L as OH): NR Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.0 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks: Q MEASURED AT CONTINUOUS GAUGING STATION. WATER CLEAR. H20 DIVERTED FROM WEST GALLATIN INTO HYALITE CREEK.
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.