Ground-Water Information Center Water Quality Report Site Name: WEST GALLATIN AT DRY CREEK RD WGDCRD
Report Date: 4/23/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 200764 / 257458 Sample Date: 9/16/2011 12:20:00 PM
Location (TRS): 01N 03E 12 AB Agency/Sampler: MBMG / HENNE, BILL
Latitude/Longitude: 45° 51' 36" N 111° 17' 26" W Field Number: WGDCRD
Datum: NAD83 Lab Date: 12/20/2011 7:36:09 AM
Altitude: Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: STREAM Procedure Type: DISSOLVED
Geology: Staff Gage Reading: NR
USGS 7.5' Quad: MANHATTAN Stream Stage: NR
PWS Id: Stream Discharge (cfs): NR  -  NR
Project: BWIPMN Stream Width (ft): NR  -  NR
Sample Water Use: Sample Depth (ft): NR  -  NR
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 40.150 2.003 Bicarbonate (HCO3) 142.580 2.337
Magnesium (Mg) 11.170 0.919 Carbonate (CO3) 1.940 0.069
Sodium (Na) 4.350 0.189 Chloride (Cl) 1.860 0.052
Potassium (K) 2.110 0.054 Sulfate (SO4) 34.120 0.711
Iron (Fe) 0.006 J 0.000 Nitrate (as N) <0.010 U 0.000
Manganese (Mn) 0.003 J 0.000 Fluoride (F) 0.190 0.010
Silica (SiO2) 12.720 Orthophosphate (as P) <0.020 U 0.000
Total Cations 3.171 Total Anions 3.180
Trace Element Results (µg/L)
Aluminum (Al): 0.768 J Cesium (Cs): <0.100 U Molybdenum (Mo): 0.800 Strontium (Sr): 200.910
Antimony (Sb): <0.100 U Chromium (Cr): 0.180 J Nickel (Ni): 0.690 Thallium (Tl): <0.100 U
Arsenic (As): 0.730 Cobalt (Co): 0.140 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 52.780 Copper (Cu): 0.300 J Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): <0.100 U Titanium (Ti): 0.380 J
Boron (B): 7.070 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): <10.000 U Lead (Pb): <0.040 U Rubidium (Rb): 1.090 Uranium (U): 0.840
Cadmium (Cd): <0.100 U Lithium (Li): 2.820 Silver (Ag): <0.100 U Vanadium (V): 0.850
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): <0.100 U Zinc (Zn): 1.470
Zirconium (Zr): <0.100 U
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 178.76 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 251.32 Hardness as CaCO3: 146.23 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 295 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 312.3 Alkalinity as CaCO3 (mg/L): 120.62 Phosphorus, TD (mg/L): <0.010 U
Field pH: 8.54 Ryznar Stability Index: 7.280 Field Nitrate (mg/L): NR
Lab pH: 8.35 Sodium Adsorption Ratio: 0.1439 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 15 Langlier Saturation Index: 0.535 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) <0.200 U Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) <1.000 U Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.