Ground-Water Information Center Water Quality Report Site Name: SMETANA, DUSAN 
Report Date: 3/28/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 200470 / 214855 Sample Date: 8/9/2011 2:35:00 PM
Location (TRS): 01S 04E 22 CCCB Agency/Sampler: MBMG / MASON, DONALD
Latitude/Longitude: 45° 43' 50" N 111° 13' 35" W Field Number: 214855
Datum: NAD83 Lab Date: 11/22/2011 2:27:20 PM
Altitude: 4535 Lab/Analyst: MBMG / MCGRATH, STEVE
County/State: GALLATIN / MT Sample Method/Handling: GRAB / ru:1 ra:0 fu:1 fa:2
Site Type: WELL Procedure Type: DISSOLVED
Geology: 120SNGR Total Depth (ft): 140
USGS 7.5' Quad: BOZEMAN HOT SPRINGS SWL-MP (ft): 4.08
PWS Id: Depth Water Enters (ft): NR
Project: GWCP08
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 103.630 5.171 Bicarbonate (HCO3) 404.530 6.630
Magnesium (Mg) 25.760 2.120 Carbonate (CO3) 0.000 0.000
Sodium (Na) 24.400 1.061 Chloride (Cl) 8.560 0.241
Potassium (K) 3.460 0.089 Sulfate (SO4) 55.180 1.149
Iron (Fe) <0.002 U 0.000 Nitrate (as N) 2.920 0.208
Manganese (Mn) 0.001 J 0.000 Fluoride (F) 0.140 0.007
Silica (SiO2) 23.060 Orthophosphate (as P) <0.020 U 0.000
Total Cations 8.460 Total Anions 8.237
Trace Element Results (µg/L)
Aluminum (Al): 32.350 Cesium (Cs): <0.100 U Molybdenum (Mo): 0.390 J Strontium (Sr): 460.590
Antimony (Sb): <0.100 U Chromium (Cr): 0.150 J Nickel (Ni): 0.130 J Thallium (Tl): <0.100 U
Arsenic (As): 0.580 Cobalt (Co): 0.110 J Niobium (Nb): <0.100 U Thorium (Th): <0.100 U
Barium (Ba): 124.450 Copper (Cu): 1.980 Neodymium (Nd): <0.100 U Tin (Sn): <0.100 U
Beryllium (Be): <0.100 U Gallium (Ga): <0.100 U Palladium (Pd): 0.390 J Titanium (Ti): 0.630
Boron (B): 48.910 Lanthanum (La): <0.100 U Praseodymium (Pr): <0.100 U Tungsten (W): <0.100 U
Bromide (Br): 91.000 Lead (Pb): <0.040 U Rubidium (Rb): 4.300 Uranium (U): 7.080
Cadmium (Cd): <0.100 U Lithium (Li): 2.290 Silver (Ag): <0.100 U Vanadium (V): 0.880
Cerium (Ce): <0.100 U Mercury (Hg): NR Selenium (Se): 0.930 Zinc (Zn): <0.200 U
Zirconium (Zr): 0.120 J
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 445.93 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 651.42 Hardness as CaCO3: 364.79 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 683 Field Alkalinity as CaCO3 (mg/L): 325 PCP (µg/L): NR
Lab Conductivity (µmhos): 831.4 Alkalinity as CaCO3 (mg/L): 332.17 Phosphorus, TD (mg/L): <0.010 U
Field pH: 7.48 Ryznar Stability Index: 6.516 Field Nitrate (mg/L): 3.000
Lab pH: 7.41 Sodium Adsorption Ratio: 0.5468 Field Dissolved O2 (mg/L): 1.080
Water Temp (°C): 9.4 Langlier Saturation Index: 0.447 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): <0.010 U Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) 2.750 Hydroxide (mg/L as OH): 0.000 Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) 2.900 Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: J = Estimated quantity above detection limit but below reporting limit; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.