Ground-Water Information Center Water Quality Report Site Name: VALLEY WEST TRAILER COURT PUBLIC WATER SUPPLY SYSTEM SAMPLE 
Report Date: 4/26/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 2001Q0966 / 184164 Sample Date: 11/2/2000 10:30:00 AM
Location (TRS): 12N 20W 34 DDCC Agency/Sampler: MBMG / PMN
Latitude/Longitude: 46° 44' 53" N 114° 5' 33" W Field Number:
Datum: NAD27 Lab Date: 11/30/2000
Altitude: 00444001 Lab/Analyst: MBMG / JMC
County/State: MISSOULA / MT Sample Method/Handling: PUMPED / 3120
Site Type: PUBLIC WATER SUPPLY - GW Procedure Type: DISSOLVED
Geology: 111ALVM
USGS 7.5' Quad: FLORENCE
PWS Id: 00444001
Project: PWSINV, BWIPLOLITHX
Sample Water Use: PUBLIC WATER SUPPLY
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 18.600 0.928 Bicarbonate (HCO3) 88.100 1.444
Magnesium (Mg) 4.930 0.406 Carbonate (CO3) 0.000 0.000
Sodium (Na) 3.120 0.136 Chloride (Cl) 1.240 0.035
Potassium (K) 1.070 0.027 Sulfate (SO4) 2.540 0.053
Iron (Fe) <.005 0.000 Nitrate (as N) 0.058 0.004
Manganese (Mn) <.001 0.000 Fluoride (F) <.05 0.000
Silica (SiO2) 13.300 Orthophosphate (as P) <.05 0.000
Total Cations 1.498 Total Anions 1.536
Trace Element Results (µg/L)
Aluminum (Al): <30 Cesium (Cs): NR Molybdenum (Mo): <10 Strontium (Sr): 39.600
Antimony (Sb): <2 Chromium (Cr): 2.450 Nickel (Ni): <2 Thallium (Tl): <5
Arsenic (As): <1 Cobalt (Co): <2 Niobium (Nb): NR Thorium (Th): NR
Barium (Ba): 29.400 Copper (Cu): <2 Neodymium (Nd): NR Tin (Sn): NR
Beryllium (Be): <2 Gallium (Ga): NR Palladium (Pd): NR Titanium (Ti): <1
Boron (B): <30 Lanthanum (La): NR Praseodymium (Pr): NR Tungsten (W): NR
Bromide (Br): <50 Lead (Pb): <2 Rubidium (Rb): NR Uranium (U): NR
Cadmium (Cd): <2 Lithium (Li): 1.660 Silver (Ag): <1 Vanadium (V): <5
Cerium (Ce): NR Mercury (Hg): NR Selenium (Se): <1 Zinc (Zn): 3.360
Zirconium (Zr): <2
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 87.88 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 132.53 Hardness as CaCO3: 66.74 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 143 Field Alkalinity as CaCO3 (mg/L): NR PCP (µg/L): NR
Lab Conductivity (µmhos): 150 Alkalinity as CaCO3 (mg/L): 72.18 Phosphorus, TD (mg/L): <.05
Field pH: 7.7 Ryznar Stability Index: 9.114 Field Nitrate (mg/L): NR
Lab pH: 7.63 Sodium Adsorption Ratio: 0.1598 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 7.1 Langlier Saturation Index: -0.742 Field Chloride (mg/L): NR
Air Temp (°C): 10 Nitrite (mg/L as N): <.05 Field Redox (mV): NR
Nitrate + Nitrite (mg/L as N) NR Hydroxide (mg/L as OH): NR Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) NR Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition:
Field Remarks: SAMPLE FROM SYSTEM SUPPLIED BY 5 WELLS M#S 171788/ 171789/ 67449/ 67457/ 67458 COLIFORM ABSENT
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: A = Hydride atomic absorption; E = Estimated due to interference; H = Exceeded holding time; J = Estimated quantity above detection limit but below reporting limit; K = Na+K combined; N = Spiked sample recovery not within control limits; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.