Ground-Water Information Center Water Quality Report Site Name: VALITON DON 
Report Date: 5/2/2024 Compare to Water Quality Standards

Location Information
Sample Id/Site Id: 2001Q0362 / 149170 Sample Date: 8/7/2000 1:00:00 PM
Location (TRS): 15N 11W 19 BCAA Agency/Sampler: MBMG / JKF
Latitude/Longitude: 47° 2' 43" N 113° 2' 38" W Field Number: 149170
Datum: NAD27 Lab Date: 12/18/2000
Altitude: 4435 Lab/Analyst: MBMG / JMC
County/State: POWELL / MT Sample Method/Handling: PUMPED / 4220
Site Type: WELL Procedure Type: DISSOLVED
Geology: 112SNGR Total Depth (ft): 55
USGS 7.5' Quad: OVANDO MOUNTAIN SWL-MP (ft): 15.89
PWS Id: Depth Water Enters (ft): 40
Project: GWCP05
Major Ion Results
mg/L meq/L mg/L meq/L
Calcium (Ca) 126.000 6.287 Bicarbonate (HCO3) 423.600 6.943
Magnesium (Mg) 24.300 2.000 Carbonate (CO3) 0.000 0.000
Sodium (Na) 38.900 1.692 Chloride (Cl) 1.130 0.032
Potassium (K) 1.500 0.038 Sulfate (SO4) 139.000 2.895
Iron (Fe) 4.080 0.146 Nitrate (as N) <.5 P 0.000
Manganese (Mn) 0.745 0.027 Fluoride (F) 0.117 0.006
Silica (SiO2) 23.400 Orthophosphate (as P) <.5 0.000
Total Cations 10.204 Total Anions 9.876
Trace Element Results (µg/L)
Aluminum (Al): <30 Cesium (Cs): NR Molybdenum (Mo): <10 Strontium (Sr): 430.000
Antimony (Sb): <2 Chromium (Cr): <2 Nickel (Ni): 2.670 Thallium (Tl): <5
Arsenic (As): <1 Cobalt (Co): <2 Niobium (Nb): NR Thorium (Th): NR
Barium (Ba): 70.200 Copper (Cu): <2 Neodymium (Nd): NR Tin (Sn): NR
Beryllium (Be): <2 Gallium (Ga): NR Palladium (Pd): NR Titanium (Ti): <1
Boron (B): 32.500 Lanthanum (La): NR Praseodymium (Pr): NR Tungsten (W): NR
Bromide (Br): <50 Lead (Pb): <2 Rubidium (Rb): NR Uranium (U): NR
Cadmium (Cd): <2 Lithium (Li): 57.100 Silver (Ag): <1 Vanadium (V): <5
Cerium (Ce): NR Mercury (Hg): NR Selenium (Se): <1 Zinc (Zn): 11.800
Zirconium (Zr): 2.100
Field Chemistry and Other Analytical Results
**Total Dissolved Solids (mg/L): 568.18 Field Hardness as CaCO3 (mg/L): NR Ammonia (mg/L): NR
**Sum of Diss. Constituents (mg/L): 783.31 Hardness as CaCO3: 414.64 T.P. Hydrocarbons (µg/L): NR
Field Conductivity (µmhos): 834 Field Alkalinity as CaCO3 (mg/L): 384 PCP (µg/L): NR
Lab Conductivity (µmhos): 831 Alkalinity as CaCO3 (mg/L): 347.75 Phosphorus, TD (mg/L): 0.089
Field pH: 7.3 Ryznar Stability Index: 6.137 Field Nitrate (mg/L): 0.500
Lab pH: 7.58 Sodium Adsorption Ratio: 0.8334 Field Dissolved O2 (mg/L): NR
Water Temp (°C): 7.4 Langlier Saturation Index: 0.722 Field Chloride (mg/L): NR
Air Temp (°C): NR Nitrite (mg/L as N): NR Field Redox (mV): -25.4
Nitrate + Nitrite (mg/L as N) NR Hydroxide (mg/L as OH): NR Lab, Dissolved Organic Carbon (mg/L): NR
Total Kjeldahl Nitrogen (mg/L as N) NR Lab, Dissolved Inorganic Carbon (mg/L): NR Lab, Total Organic Carbon (mg/L): NR
Total Nitrogen (mg/L as N) NR Acidity to 4.5 (mg/L CaCO3) NR Acidity to 8.3 (mg/L CaCO3) NR
As(III) (ug/L) NR As(V) (ug/L) NR Total Susp Solids (mg/L) NR
Notes
Sample Condition: CLEAR
Field Remarks:
Lab Remarks:
Explanation: mg/L = milligrams per Liter; µg/L = micrograms per Liter; ft = feet; NR = No Reading in GWIC
Qualifiers: A = Hydride atomic absorption; E = Estimated due to interference; H = Exceeded holding time; J = Estimated quantity above detection limit but below reporting limit; K = Na+K combined; N = Spiked sample recovery not within control limits; P = Preserved sample; S = Method of standard additions; U = Undetected quantity below detection limit; * = Duplicate analysis not within control limits; ** = Sum of Dissolved Constituents is the sum of major cations (Na, Ca, K, Mg, Mn, Fe) and anions (HCO3, CO3, SO4, Cl, SiO2, NO3, F) in mg/L. Total Dissolved Solids is reported as equivalent weight of evaporation residue.
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.